Showing posts with label Cryogenic Freezers. Show all posts
Showing posts with label Cryogenic Freezers. Show all posts

Friday, February 3, 2012

LN2 Freezers Help Companies Play New Age Tooth Fairy by Storing Dental Stem Cells

Slipping your children's teeth under the pillow for the tooth fairy may be a thing of the past. Now, thanks to LN2 freezer (liquid nitrogen) technology, companies are offering services to store baby teeth in case they are needed in the future to help treat or cure serious family medical issues.

The new technology allows companies to bank adult stem cells found in baby teeth and even in wisdom teeth. So instead of throwing those teeth away or having a dentist discard extracted wisdom teeth people can now store these precious dental stem cells that can be used for various dental and medical applications.

The lab harvests pulp and tissue that contains stem cells and then processes the cells for freezing. The cells are equilibrated with cyroprotectant and then placed in LN2 freezer storage units at the company. This will ensure long-term storage until the possible need by a healthcare provider.

The cost to store a tooth is just under $800 which includes the first year of storage after that fees fall about $10 a month to keep the tooth frozen.

As of right now there are no medical applications using dental stem cells but they are being used in studies. There is hope that one day – thanks to the help of LN2 freezer technology – doctors will be able to treat spinal cord injuries, MS (multiple sclerosis) and a variety of other issues.

So the next time the tooth fairy is in town, think about keeping that tooth instead of trading it in for a shiny coin. Who knows, that tooth may be worth someone's life down the road!

Thursday, February 2, 2012

Use Princeton Cryo's High-Quality Cryogenic Equipment to Avoid Fines

Cryogenic freezing can certainly be dangerous. That's why we provide the best-quality cryogenic equipment possible to ensure the safety and effectiveness of all cryogenic freezing systems.

With our products you can avoid problems and fines like one large frozen pizza company who was cited for nine alleged safety and health violations. Of course, most of the fines were of a result of neglect of the company, but you can make the cryogenic freezing process easier with our products.

One of the citations was a violation of exposing workers to an oxygen deficient atmosphere.

"Employers are responsible for knowing the hazards that exist in their workplace and training workers in proper safety precautions such as air monitoring and respirator use," said Kim Stille, director of OSHA's Madison Area Office. "OSHA is committed to protecting workers, especially when employers fail to do so."

The fines totaled $76,300 after OSHA initiated an inspection of the pizza company's plant in June. The violations were issued when workers were exposed to an oxygen deficient environment during the freezing process of the pizzas in a liquid nitrogen cryogenic freezer. The cryogenic freezer created a hazardous environment due to the buildup of nitrogen gas; however, no injuries or illnesses were reported as a result of the conditions.

Other fines focused on the lack of training and implementation of safety equipment. These fines can greatly hurt any company that uses cryogenic equipment. That's why we, at Princeton Cryo, think it's important to use the best equipment in the market. We strive to create a safe environment no matter what the use of the cryogenic freezer.

Tuesday, January 31, 2012

The Useful But Dangerous Liquid Nitrogen

We've all heard the uses of liquid nitrogen and its unique properties that help scientists around the world discover new and amazing things. However, without the proper liquid nitrogen equipment and other precautions, the substance can quickly become very dangerous to those around the substance.

Recently, an astrophysicist in Egypt was cooling a charged coupled device camera for the observatory's telescope. He was carrying a cryogenic storage vacuum flask of liquid nitrogen which was to contain the heat coming off of the camera. The flask exploded, giving the astrophysicist severe chest and hand cold burns from the bursting liquid nitrogen.

Liquid nitrogen transfers to nitrogen gas of a rapid ration of 1:694, which is why the substance exploded. If you pour two gallons of liquid nitrogen into any warm vacuum it suddenly and immediately evaporates into a gas in front of your eyes. The properties of the substance are very dangerous for those who are unfamiliar with the safety precautions or liquid nitrogen equipment.

The gas is used for observatory and lab work but is more commonly used in refrigeration. Foods and goods can be transported around the world with the use of cryogenic storage. Liquid nitrogen is also vital in the cryopreservation of blood, reproductive cells and other biological samples.

It's also used in low temperature medical treatment in some dermatology cases. Also, construction companies may be able to use liquid nitrogen to freeze damaged water pipes and stopping water leaks during the fixing process. In the military, liquid nitrogen is used in heat-seeking missiles to prevent sensors from getting confused by their own heat signals or by the heat form the planes that are launching them.

There are so many applications of liquid nitrogen, but you need the proper liquid nitrogen equipment to ensure that the safety of everyone is preserved.

Tuesday, January 3, 2012

We Stand By Our Products With a 100 Percent Guarantee

We at PrincetonCryo.com believe in valuing our customer's satisfaction with all of our products. We offer a first-rate customer service that can help your needs, which can prove invaluable in the world of cryogenics.

We offer top of the line cryogenic equipment to help you build the best cryogenic storage system on the market. PrincetonCryo.com provides industry-leading cryogenic design and engineers that are instrumental in creating the most well-renowned equipment in the world. Our engineers are experience and well trained to design and install all of our cryogenic equipment.

Because we have set a high bar for ourselves and have earned the reputation as a reliable, high-quality leader in the cryogenic industry, we know that all of our customers will have 100 percent satisfaction.

If you do not have 100 percent satisfaction, we adhere to a "No Hassle" return policy where we'll make sure your cryogenic equipment is working correctly or you'll get your money back. So if you're in the field that needs cryogenic storage equipment then look no further than PrincetonCryo.com, we guarantee you'll be satisfied.

Wednesday, December 21, 2011

Types of biological materials that can be held in Cryogenic Storage

Cryogenic storage is very helpful when storing biological materials. Because a cryogenic freezer can freeze things at -150 degrees Celsius (refrigerated storage is about 5 degrees Celsius and typical freezer storage is about -20 degrees Celsius), it can store many biological materials without letting them go bad.
Some of the biological materials that can be stored are:

- Blood
- Plasma
- Bone
- DNA
- RNA
- Explant device storage (hips, mesh, etc.)
- Tissues and cell lines
- Agro and plant samples
- Pathology and legal specimens
- Stem cells and cord blood
- Fluids and urine
- Clinical supplies
- Serum
- Slides

This is just some of the things that can be held in cryogenic storage. The control of the temperature of valuable biological materials is very important. From storing sperm samples, blood samples to even ways of storing food, cryogenic freezing is one of the best ways to ensure pristine preservation.

Labs that have cryogenic freezers are more likely to have more beneficial biological samples and have more accurate tests for blood, DNA or other animal tissues. Thanks to cryogenic storage, biological materials can be held for a long time and won't spoil or deteriorate. This is important in guaranteeing to those who need biological specimens preserved.

Monday, November 16, 2009

Stem Cell Research

The first human embryonic stem cell treatment approved by the FDA for human testing has been shown to restore limb function in rats with neck spinal cord injuries - a finding that could expand the clinical trial to include people with cervical damage.

Full Story:

http://www.uci.edu/features/feature_cervicalstemcells_091109.php

Tuesday, October 27, 2009

New Developments

Growing Cartilage from Stem Cells
Using adult stem cells from bone marrow and skin as well as human embryonic stem cells, researchers have grown cartilage tissue in the lab (UC Davis)

Neural Stem Cells Show Promise for Treating Age-Related Macular Degeneration
StemCells, Inc. announced recently new preclinical data showing that its human neural stem cells protect cone photoreceptors in the eye from progressive degeneration and preserve visual function long term. (StemCells, Inc., Palo Alto)

Monday, January 12, 2009

Gordinier Cryogenic Tank Switcher

To work with the TEC 3000, Gordinier has developed a cryogenic tank switcher, but it only works with correct installation. If installed improperly, the cryogenic tank switcher can cause the cryogenic freezer to fire the hot gas bypass solenoid at all times when connected to the cryogenic freezer. This results in pouring liquid nitrogen onto the floor of the facility. The cryogenic freezer functions normally when the Gordineir equipment is installed properly.

In two seperate places, this tank switcher splices into the wiring of the TEC 3000. Between the controller and the 12 pin connector is the first place at the bottom of the TEC 3000. Between display panel and the RJ45 connector that plugs into the display is the second place is inside the controller. This version of Gordineir’s tank switcher only functions properly if a certified Gordinier technician installs the switcher. Chart MVE has said that the customer voids the 2 year warranty of the controller if a Gordineir switcher has been hooked up to one of Chart’s TEC 3000 units.

Friday, January 9, 2009

Cryogenic Temperature Sensor Probes

Although TEC 3000 use different temperature probes in liquid nitrogen freezers, the function is identical when compared to TEC 2000. The TEC 2000 uses only two wires and hence the temperature probe casing has a smaller diameter. On the other hand, the TEC 3000 uses three wire as a result it has a larger diameter (despite the fact that only two of those three wires are in use). They carry an accuracy of 0.12% in which both are 1000 ohm platinum RTDs. Keep in mind that the temperature with an precision of plus or minus 2°C is displayed by TEC 3000 controller.